LogTag® TRIX-16

Record temperature and humidity at little cost  Reliable, uncomplicated, credit card sized  Unbeaten value for money

The LogTag ® TRIX-16 is a versatile, wide range, multi-trip Temperature Recorder, featuring high resolution temperature readings over a measurement range of -40°C to +85°C (-40°F to +185°F) for up to 16,000 recordings - enough for the longest trip. The LogTag ® TRIX-16 features a real time clock, which provides date/ time stamps for each temperature reading and complies with the relevant international standards for temperature monitoring devices, such as FCC, CE, C-TICK, and RoHS

  • A real time clock provides date/time stamps for each temperature reading.

  • Up to 16,000 recordings - enough for the longest trip.

  • In-transit inspections at the push of a button.

  • Industry best download time - less than 5 seconds for full memory.

  • Comprehensive customization options including alarm settings, sample interval and trip duration.

  • Fixed Battery provides 1 year storage, followed by 2 – 3 years of normal use.

     

    LogTag Trix-16

    Sensor Measurement Range

    -40°C to +85°C (-40°F to +185°F)

    Operating Temperature Range

    -40°C to +85°C (-40°F to +185°F)

    Storage Temperature Range

    -30°C to +55°C (-22°F to +131°F)

    Rated Temperature Reading Resolution

    Less than 0.1°C for -40°C to +40°C.
    Less than 0.2°C for +40°C to +80°C.
    Less than 0.4°C for +80°C to +85°C

    Rated Temperature Reading Accuracy

    Better than ±0.5°C for -20°C to +40°C.
    Better than ±0.7°C for -30°C to -20°C and +40°C to +60°C.
    Better than ±0.8°C for +60°C to +85°C.
    Better than ±0.9°C for -40°C to -30°C.

    Sensor Reaction Time

    Typically less than 5 minutes (T90) in moving air (1m/s)

    Recording Capacity

    16,159 temperature readings. 112 days @ 10min logging, 168 days @ 15min logging.

    Sampling Interval

    Configurable from 30 seconds to several hours

    Logging Start Options

    Push button start or specific date & time. Optional start delay of up to 18 hours

    Recording Indication

    Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator.

    Alarms

    1 configurable upper and 1 configurable lower alarms

    Download Time

    Typically less than 10 seconds for full memory (16,159 readings), depending on computer or readout device used.

    Environmental

    IP65 (roughly equivalent to NEMA 4)

    Power Source

    CR2450 3V LiMnO2  (Battery (Fixed)

    Battery Life

    1 year storage, followed by 2 – 3 years of normal use (based on 15 minute logging, download data monthly

    Connection Interface

    LTI-HID interface cradle

    Software

    LogTag Analyzer

    Size

    86mm(H) x 54.5mm(W) x 8.6mm(T).

    Weight

    33g

    Case Material

    Polycarbonate.