Chat with us, powered by LiveChat
Discover our

Vaisala Temperature & Humidity Loggers

The Vaisala validation system is a powerful, easy-to-use alternative to thermocouple-based equipment and bulky data acquisition systems.

Vaisala data loggers are a versatile and reliable replacement for chart recorders and bulky data acquisition systems, ideal for mapping/validation, the data loggers provide high accuracy humidity and/or temperature measurement and recording.

A complete solution, our mapping tools eliminate costly downtime from pre- and post-calibration and deliver accurate, validatable results.

This is ideal for standalone applications like validation / mapping, primary system back-up, and critical product transport or connected to your network for real-time monitoring, alarming, and data archiving. Data recording capabilities include accurate time-based readings up to six times per minute, for durations lasting up to several years. No charts, wires, connections or power cords are required.

Vaisala's humidity and temperature validation solution is the easiest, most cost-effective method for mapping equipment, areas, and systems in FDA regulated and GxP environments.

Through pioneering and innovative engineering, the company has developed small, compact, superior monitoring and recording tools that provide unmatched accuracy and integrity for temperature and humidity monitoring and validation applications

Connectivity options provide an easy, scalable network capability using Ethernet and/or WiFi for remote and centralised monitoring, real-time data display, data redundancy and email alarms.

With accredited temperature and humidity calibration services and quality customer support, the data loggers offer a completely integrated solution for all your continuous monitoring and reporting or validation/ mapping applications.

Browser based ViewLinc software delivers real time continuous viewing, monitoring and alarm alerts to cell phones, local or networked PC's providing immediate notification of out of compliance conditions in critical applications.

Validatable Relative Humidity Logger DL-2000

Type of Sensor Integrated high-accuracy capacitive polymer RH sensor
Initial Accuracy +/-1%RH over 10%RH to 90%RH at +20ºC to +30ºC
+/-2%RH over 10%RH to 90%RH at -20ºC to +70ºC
Operating range -35°C to 85°C (-31°F to 185°F) and
0% RH to 100% RH
Resolution 0.05% RH
1-year Accuracy

+/-2% RH over 10% RH to 90% RH at +20°C to +30°C

+/-3% RH over 10% RH to 90% RH at -20°C to +70°C
Calibration verification Annual (recommended)

Initial Accuracy

+/-0.10ºC over +20ºC to +30ºC
+/-0.15ºC over -25ºC to +70ºC
Operating range -35°C to 85°C (-31°F to 185°F)
Resolution 0.02°C at 25°C
1-year Accuracy +/-0.15°C over 20°C to +30°C

+/-0.25°C over -25°C to +70°C

Memory Type

Non-volatile EEROM
Data Sample Capacity 35,100 12-bit samples
Memory Modes User-selectable: Wrap when memory full (FIFO), or Stop when memory full.
Memory Protection Data retention > 20 years backup without power.
Sampling Rates

User-selectable (in intervals of 10 seconds) from once every 10 seconds to once a day.

Size

2.8 x 2.1 x 0.8" (71x53x20mm);
65g (2.4 oz)
Operating Range -35°C to 85°C (-31°F to 185°F) and
0% RH to 100% RH
Interfaces RS-232 serial, USB, Ethernet, PoE, WiFi network interface available.
Mounting Magnetic strips; 3M Dual Lock™ fasteners
PC Software

Designed for use with vLog Software and Veriteq viewLinc (for on-going monitoring & alarming)

Clock Accuracy: +/- 1 min./month at -25°C to +70°C
Electromagnetic Compatibility FCC Part 15 and CE
Power Source Internal lithium battery with life of 10 years at 1 minute sampling rate.

Validatable 2 Channel Temp Logger DL-1016

Initial Accuracy

+/-0.25ºC over -90ºC to +50ºC
+/-0.15ºC over -25ºC to +70ºC
Operating range -90°C to +70°C (-139°F to 158°F)
Resolution 0.01°C at +25°C
1-year Accuracy +/-0.35°C over -90°C to +30°C

+/-0.25°C over -25°C to +50°C

Initial Accuracy

+/-0.10ºC over +20ºC to +30ºC
+/-0.15ºC over -25ºC to +70ºC
Operating range -35°C to 85°C (-31°F to 185°F)
Resolution 0.02°C at 25°C
1-year Accuracy +/-0.15°C over 20°C to +30°C

+/-0.25°C over -25°C to +70°C

Size

2.8 x 2.1 x 0.8" (71x53x20mm);
65g (2.4 oz)
Operating Range -95°C to +70°C (-139°F to 158°F)
0% RH to 100% RH
Interfaces RS-232 serial, USB, Ethernet, PoE, WiFi network interface available.
Mounting Magnetic strips; 3M Dual Lock™ fasteners
PC Software

Designed for use with vLog Software and Veriteq viewLinc (for on-going monitoring & alarming)

Clock Accuracy: +/- 1 min./month at 0 to +50°C
Electromagnetic Compatibility FCC Part 15 and CE
Power Source Internal lithium battery with life of 10 years at 1 minute sampling rate.

Validatable 4 Channel Temperature Logger DL-1416

Initial Accuracy

+/-0.25ºC over -90ºC to +50ºC
+/-0.15ºC over -25ºC to +70ºC
Operating range -90°C to +70°C (-139°F to 158°F)
Resolution 0.01°C at +25°C
1-year Accuracy +/-0.35°C over -90°C to +30°C

+/-0.25°C over -25°C to +50°C

Memory Type

Non-volatile EEROM
Data Sample Capacity 68 600 16-bit samples
Memory Modes User-selectable: Wrap when memory full (FIFO), or Stop when memory full.
Memory Protection Data retention > 20 years backup without power.
Sampling Rates

User-selectable (in intervals of 10 seconds) from once every 10 seconds to once a day.

Size

2.8 x 2.1 x 0.8" (71x53x20mm);
65g (2.4 oz)
Operating Range -95°C to +70°C (-139°F to 158°F)
0% RH to 100% RH
Interfaces RS-232 serial, USB, Ethernet, PoE, WiFi network interface available.
Mounting Magnetic strips; 3M Dual Lock™ fasteners
PC Software

Designed for use with vLog Software and Veriteq viewLinc (for on-going monitoring & alarming)

Clock Accuracy: +/- 1 min./month at 0 to +50°C
Electromagnetic Compatibility FCC Part 15 and CE
Power Source Internal lithium battery with life of 10 years at 1 minute sampling rate.

Validatable 4 Channel Universal Logger DL-4000

Initial Accuracy

+/-0.10ºC over +20ºC to +30ºC
+/-0.15ºC over -25ºC to +70ºC
Operating range -35°C to 85°C (-31°F to 185°F)
Resolution 0.02°C at 25°C
1-year Accuracy +/-0.15°C over 20°C to +30°C

+/-0.25°C over -25°C to +70°C

Memory Type

Non-volatile EEPROM
Data Sample Capacity 120 000 12-bit samples
Memory Modes User-selectable: Wrap when memory full (FIFO), or Stop when memory full.
Memory Protection Data retention > 20 years backup without power.
Sampling Rates

User-selectable (in intervals of 10 seconds) from once every 10 seconds to once a day.

Size

3.4 x 2.3 x 1" (71x53x20mm);
76g (2.7 oz)
Operating Range -40°C to 85°C (-40°F to 185°F) and
0% RH to 100% RH
Interfaces RS-232 serial, USB, Ethernet, PoE, WiFi network interface available.
Mounting Magnetic strips; 3M Dual Lock™ fasteners
PC Software

Designed for use with vLog Software and Veriteq viewLinc (for on-going monitoring & alarming)

Clock Accuracy: +/- 1 min./month at -25°C to +70°C
Electromagnetic Compatibility FCC Part 15 and CE
Power Source Internal lithium battery with life of 10 years at 1 minute sampling rate.

Thermocouple Data Logger DL-1700

Input Range

-7.2 to +55.4 mV
Initial Accuracy +0.042 mV at 25°C
1-year Accuracy +/-0.055mV at +25°C
Resolution 0.016mV
Temperature Measurement Range Accuracy at Mid-Range Resolution at Mid-Range
Type K -220... +1370°C +1.3°C 0.37°C
Type J -130...+900°C +1.0°C 0.29°C
Type T -240...+350°C +1.2°C 0.34°C

Size

3.4 x 2.1 x 1" (85x59x26mm);
60g (2.7 oz)
Operating Range -40°C to 85°C (-40°F to 185°F) and
0% RH to 100% RH
Interfaces RS-232 serial, USB, Ethernet, WiFi network interface available.
Mounting Magnetic strips; 3M Dual Lock™ fasteners
PC Software

Designed for use with vLog Software and Veriteq viewLinc (for on-going monitoring & alarming)

Clock Accuracy: +/- 1 min./month at -25°C to +70°C
Electromagnetic Compatibility FCC Part 15 and CE
Power Source Internal lithium battery with life of 10 years at 1 minute sampling rate.

Memory Type

Non-volatile EEPROM
Data Sample Capacity 135 165 12-bit samples
Memory Modes User-selectable: Wrap when memory full (FIFO), or Stop when memory full.
Memory Protection Data retention > 20 years backup without power.
Sampling Rates

User-selectable (in intervals of 10 seconds) from once every 10 seconds to once a day.

 

Vaisala Logger Techical Data Sheets

 

vLog - Validatable Data Logger Software

ViewLinc Software

Viewlinc software
Validatable datalogger software version offers complete datalogger communication, graphing and reporting functions.
ViewLinc Software
ViewLinc software for monitoring, alarming and reporting