Vaisala Temperature and Humidity Loggers
The Vaisala validation system is a powerful, easy-to-use alternative to thermocouple-based equipment and bulky data acquisition systems.
A Vaisala temperature and humidity logger is versatile and reliable, serving a unique replacement for chart recorders and bulky data acquisition systems. Discover the temperature and humidity logger that is ideal for both mapping and validation. Vaisala data loggers provide high accuracy humidity and/or temperature measurement and recording.
As a complete solution, Vaisala mapping tools eliminate costly downtime from pre- and post-calibration and deliver accurate, valid results.
Who choose a Vaisala temperature and humidity logger?
This is ideal for standalone applications like validation / mapping, primary system back-up, and critical product transport or connected to your network for real-time monitoring, alarming, and data archiving. Data recording capabilities include accurate time-based readings up to six times per minute, for durations lasting up to several years. No charts, wires, connections or power cords are required.
Vaisala's temperature and humidity logger offers a validation solution that is user friendly, cost-effective and precise for accurate mapping of equipment, areas, and systems in FDA regulated and GxP environments.
Through pioneering and innovative engineering, the company has developed small, compact, superior monitoring and recording tools that provide unmatched accuracy and integrity for temperature and humidity monitoring and validation applications.
Connectivity options provide an easy, scalable network capability using Ethernet and/or WiFi for remote and centralised monitoring, real-time data display, data redundancy and email alarms.
With accredited temperature and humidity calibration services and quality customer support, the data loggers offer a completely integrated solution for all your continuous monitoring and reporting or validation/ mapping applications.
Browser based ViewLinc software delivers real time continuous viewing, monitoring and alarm alerts to cell phones, local or networked PC's providing immediate notification of out of compliance conditions in critical applications.
VaiNet Wireless Temperature and Humidity Logger RFL100
HMP110 | HMP110T | HMP115 | HMP115T | TMP115 | |
---|---|---|---|---|---|
Measurement | RH + T | T | RH + T | T | T |
Temperature Range | -40 ... +80 °C (-40 ... +176 °F) | -40 ... +80 °C (-40 ... +176 °F) | -40 ... +60 °C (-40 ... +140 °F) | -40 ... +60 °C (-40 ... +140 °F) | -196 ... +90 °C (-320.8 ... +194 °F) |
Mounting | Cable probe only | Cable probe only | Integrated or cable probe | Integrated or cable probe | Integrated or cable probe |
Memory Type |
Non-volatile EEPROM |
---|---|
Data Sample Capacity | 30 days (43200 samples per channel) |
Memory Modes | Ring buffer (FIFO) |
Memory Protection | Data retention > 20 years backup without power. |
Sampling Rates | One sample / channel / minute (nonchangeable). |
Size |
158 × 62 × 31 mm (6.22 × 2.4 × 1.22 in) |
---|---|
254 g (8.96 oz) | |
Operating Temp Range | +2 ... +60 °C (+35.6 ... +140 °F) with alkaline batteries |
-20 ... +60 °C (-4 ... +140 °F) with lithium batteries | |
Operating Humidity | 0% RH to 100% RH |
Interfaces | Wireless. |
Mounting | Screws, tie-wrap, hook, or magnetic mounting bracket (optional accessory) |
PC Software | Designed for use with ViewLinc (for on-going monitoring & alarming) |
Clock Accuracy | ±30 s/month Synchronizes with Network Time Protocol (NTP) server |
Electromagnetic Compatibility | EN/IEC 61326-1, industrial environment |
Power Source | 2 × AA sized, 1.5 V (LR6 or FR6) |
Validatable Relative Humidity Logger DL2000
Type of Sensor | Integrated high-accuracy capacitive polymer RH sensor |
---|---|
Initial Accuracy | +/-1%RH over 10%RH to 90%RH at +20ºC to +30ºC |
+/-2%RH over 10%RH to 90%RH at -20ºC to +70ºC | |
Operating range | -35°C to 85°C (-31°F to 185°F) and |
0% RH to 100% RH | |
Resolution | 0.05% RH |
1-year Accuracy | +/-2% RH over 10% RH to 90% RH at +20°C to +30°C |
+/-3% RH over 10% RH to 90% RH at -20°C to +70°C | |
Calibration verification | Annual (recommended) |
Initial Accuracy |
+/-0.10ºC over +20ºC to +30ºC |
---|---|
+/-0.15ºC over -25ºC to +70ºC | |
Operating range | -35°C to 85°C (-31°F to 185°F) |
Resolution | 0.02°C at 25°C |
1-year Accuracy | +/-0.15°C over 20°C to +30°C |
+/-0.25°C over -25°C to +70°C |
Memory Type |
Non-volatile EEPROM |
---|---|
Data Sample Capacity | 35,100 12-bit samples |
Memory Modes | User-selectable: Wrap when memory full (FIFO), or Stop when memory full. |
Memory Protection | Data retention > 20 years backup without power. |
Sampling Rates | User-selectable (in intervals of 10 seconds) from once every 10 seconds to once a day. |
Size |
2.8 x 2.1 x 0.8" (71x53x20mm); |
---|---|
65g (2.4 oz) | |
Operating Range | -35°C to 85°C (-31°F to 185°F) and |
0% RH to 100% RH | |
Interfaces | RS-232 serial, USB, Ethernet, PoE, WiFi network interface available. |
Mounting | Magnetic strips; 3M Dual Lock™ fasteners |
PC Software | Designed for use with vLog Software and Veriteq viewLinc (for on-going monitoring & alarming) |
Clock | Accuracy: +/- 1 min./month at -25°C to +70°C |
Electromagnetic Compatibility | FCC Part 15 and CE |
Power Source | Internal lithium battery with life of 10 years at 1 minute sampling rate. |
Validatable 2 Channel Temp Logger DL1016
Initial Accuracy |
+/-0.25ºC over -90ºC to +50ºC |
---|---|
+/-0.15ºC over -25ºC to +70ºC | |
Operating range | -90°C to +70°C (-139°F to 158°F) |
Resolution | 0.01°C at +25°C |
1-year Accuracy | +/-0.35°C over -90°C to +30°C |
+/-0.25°C over -25°C to +50°C |
Memory Type |
Non-volatile EEPROM |
---|---|
Data Sample Capacity | 68 600 16-bit samples |
Memory Modes | User-selectable: Wrap when memory full (FIFO), or Stop when memory full. |
Memory Protection | Data retention > 20 years backup without power. |
Sampling Rates | User-selectable (in intervals of 10 seconds) from once every 10 seconds to once a day. |
Size |
2.8 x 2.1 x 0.8" (71x53x20mm); |
---|---|
65g (2.4 oz) | |
Operating Range | -95°C to +70°C (-139°F to 158°F) |
0% RH to 100% RH | |
Interfaces | RS-232 serial, USB, Ethernet, PoE, WiFi network interface available. |
Mounting | Magnetic strips; 3M Dual Lock™ fasteners |
PC Software | Designed for use with vLog Software and Veriteq viewLinc (for on-going monitoring & alarming) |
Clock | Accuracy: +/- 1 min./month at 0 to +50°C |
Electromagnetic Compatibility | FCC Part 15 and CE |
Power Source | Internal lithium battery with life of 10 years at 1 minute sampling rate. |
Validatable 4 Channel Temperature Logger DL1416
Initial Accuracy |
+/-0.25ºC over -90ºC to +50ºC |
---|---|
+/-0.15ºC over -25ºC to +70ºC | |
Operating range | -90°C to +70°C (-139°F to 158°F) |
Resolution | 0.01°C at +25°C |
1-year Accuracy | +/-0.35°C over -90°C to +30°C |
+/-0.25°C over -25°C to +50°C |
Memory Type |
Non-volatile EEPROM |
---|---|
Data Sample Capacity | 68 600 16-bit samples |
Memory Modes | User-selectable: Wrap when memory full (FIFO), or Stop when memory full. |
Memory Protection | Data retention > 20 years backup without power. |
Sampling Rates | User-selectable (in intervals of 10 seconds) from once every 10 seconds to once a day. |
Size |
2.8 x 2.1 x 0.8" (71x53x20mm); |
---|---|
65g (2.4 oz) | |
Operating Range | -95°C to +70°C (-139°F to 158°F) |
0% RH to 100% RH | |
Interfaces | RS-232 serial, USB, Ethernet, PoE, WiFi network interface available. |
Mounting | Magnetic strips; 3M Dual Lock™ fasteners |
PC Software | Designed for use with vLog Software and Veriteq viewLinc (for on-going monitoring & alarming) |
Clock | Accuracy: +/- 1 min./month at 0 to +50°C |
Electromagnetic Compatibility | FCC Part 15 and CE |
Power Source | Internal lithium battery with life of 10 years at 1 minute sampling rate. |
Validatable 4 Channel Universal Logger DL4000
Initial Accuracy |
+/-0.10ºC over +20ºC to +30ºC |
---|---|
+/-0.15ºC over -25ºC to +70ºC | |
Operating range | -35°C to 85°C (-31°F to 185°F) |
Resolution | 0.02°C at 25°C |
1-year Accuracy | +/-0.15°C over 20°C to +30°C |
+/-0.25°C over -25°C to +70°C |
Memory Type |
Non-volatile EEPROM |
---|---|
Data Sample Capacity | 120 000 12-bit samples |
Memory Modes | User-selectable: Wrap when memory full (FIFO), or Stop when memory full. |
Memory Protection | Data retention > 20 years backup without power. |
Sampling Rates | User-selectable (in intervals of 10 seconds) from once every 10 seconds to once a day. |
Size |
3.4 x 2.3 x 1" (71x53x20mm); |
---|---|
76g (2.7 oz) | |
Operating Range | -40°C to 85°C (-40°F to 185°F) and |
0% RH to 100% RH | |
Interfaces | RS-232 serial, USB, Ethernet, PoE, WiFi network interface available. |
Mounting | Magnetic strips; 3M Dual Lock™ fasteners |
PC Software | Designed for use with vLog Software and Veriteq viewLinc (for on-going monitoring & alarming) |
Clock | Accuracy: +/- 1 min./month at -25°C to +70°C |
Electromagnetic Compatibility | FCC Part 15 and CE |
Power Source | Internal lithium battery with life of 10 years at 1 minute sampling rate. |
Thermocouple Data Logger DL1700
Input Range |
-7.2 to +55.4 mV |
---|---|
Initial Accuracy | +0.042 mV at 25°C |
1-year Accuracy | +/-0.055mV at +25°C |
Resolution | 0.016mV |
Temperature Measurement Range | Accuracy at Mid-Range | Resolution at Mid-Range | |
---|---|---|---|
Type K | -220... +1370°C | +1.3°C | 0.37°C |
Type J | -130...+900°C | +1.0°C | 0.29°C |
Type T | -240...+350°C | +1.2°C | 0.34°C |
Memory Type |
Non-volatile EEPROM |
---|---|
Data Sample Capacity | 135 165 12-bit samples |
Memory Modes | User-selectable: Wrap when memory full (FIFO), or Stop when memory full. |
Memory Protection | Data retention > 20 years backup without power. |
Sampling Rates | User-selectable (in intervals of 10 seconds) from once every 10 seconds to once a day. |
Size |
3.4 x 2.1 x 1" (85x59x26mm); |
---|---|
60g (2.7 oz) | |
Operating Range | -40°C to 85°C (-40°F to 185°F) and |
0% RH to 100% RH | |
Interfaces | RS-232 serial, USB, Ethernet, WiFi network interface available. |
Mounting | Magnetic strips; 3M Dual Lock™ fasteners |
PC Software | Designed for use with vLog Software and Veriteq viewLinc (for on-going monitoring & alarming) |
Clock | Accuracy: +/- 1 min./month at -25°C to +70°C |
Electromagnetic Compatibility | FCC Part 15 and CE |
Power Source | Internal lithium battery with life of 10 years at 1 minute sampling rate. |