Climatic Chambers
Kambic Precision Climatic Chambers
Kambic Climatic Chambers allow you to simulate different climates and environments with ease and precision to understand the impact on the safety or quality of your products. Alternatively, these high-performance environmental test chambers can be used for quick and efficient calibration of a range of sensors. Various volumes across 3 distinct temperature ranges, custom sizes and walk-in chambers are also available.
Withnell Sensors Ltd is the exclusive distributor and after sale service provider of Kambic climatic chambers in the UK & Ireland.
Kambic is specialised in the designing, developing and manufacturing of high quality climatic chambers and controlled environment rooms. Kambic environmental test chambers offer the ideal solution for temperature and humidity testing, simulation and exposure to weather, temperature cycles, aging and stress testing.
The climatic chambers are a refined solution for research and development studies, quality control, production facilities and laboratory testing. The range of kambic carbon neutral environmental testing chambers offer the ideal solution for temperature and climatic testing, simulation and exposure to weather, temperature changes, ageing and stress testing.
Independent Advice
We are always on hand to offer expert advice and technical support. Our engineers have experience with working with a range of clients on various projects. We can help you to select the right climatic chamber to suit your requirements and our after sales care is exceptional, offering extra reassurance.
Climatic Chamber Features
- Innovative air circulation system enables a uniform and stable temperature and humidity profile across the chamber
- New controller interface (upgraded model) which includes an LCD and configurable functions
- Chamber LED illumination and doors equipped with observation glass
- USB / Ethernet connection
- Red-eye software supplied free with all chambers
- Upgraded heavy duty closing mechanism with key lock
- Highly stable and rapid humidity control via a sophisticated dew point system
- Resolution for temperature display and set-point 0.1°C
- Resolution for relative humidity display and set-point 1%rH
- Dual protection system against uncontrolled over-temperature events
- Mechanical over-temperature device shuts off heating elements if temperature exceeds maximum allowed values
- Interior chamber manufactured from Polished AISI 304 stainless steel
- Exterior panels made from powder-coated galvanised steel (RAL7035)
Accessories for Climatic Chambers:
Select from a large range of accessories including;
- Additional wire shelves
- Additional sealable side access port (Ø40 , Ø50 , Ø90)
- IQ/OQ documentation
- Extended Rh control range
Available climatic chamber models:
KK-68 CH | KK-190 CH | KK-340 CH | KK-500 CH | KK-1000 CH | |
---|---|---|---|---|---|
Volume | 68L | 190L | 340L | 500L | 1000L |
Temperature Range | +5°C to +180°C | +5°C to +180°C | +5°C to +180°C | +5°C to +180°C | +5°C to +180°C |
Relative Humidity Range | 10% to 98% | 10% to 98% | 10% to 98% | 10% to 98% | 10% to 98% |
External dimensions (WxHxD) | 650 x 1233 x 796mm | 835 x 1661 x 951 | 835 x 1881 x 1126 | 1035 x 1880 x 1381 | 1235 x 1928 x 1579 |
Internal Dimensions (WxHxD) | 410 x 475 x 350mm | 600 x 615 x 510mm | 600 x 835 x 685mm | 800 x 835 x 800mm | 1000 x 1035 x 1000mm |
Max Capacity | 40 kg | 80 kg | 100 kg | 150 kg | 200 kg |
Temperature stability | ± 0.3°C @ 5°C ± 0.05°C @ 50°C 50 % Rh ± 0.05°C @ 90°C 90 % Rh ± 0.1°C @ 180°C |
± 0.3°C @ 5°C ± 0.05°C @ 50°C 50 % Rh ± 0.05°C @ 90°C 90 % Rh ± 0.15°C @ 180°C |
± 0.3°C @ 5°C ± 0.05°C @ 50°C 50 % Rh ± 0.05°C @ 90°C 90 % Rh ± 0.1°C @ 180°C |
± 0.3°C @ 5°C ± 0.05°C @ 50°C 50% Rh ± 0.05°C @ 90°C 90 % Rh ± 0.2°C @ 180°C |
± 0.3°C @ 5°C ± 0.05°C @ 50°C 50% Rh ± 0.05°C @ 90°C 90 % Rh ± 0.2°C @ 180°C |
Temperature Uniformity | ± 2.5°C @ 5°C ± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1.5°C @ 180°C |
± 1.0°C @ 5°C ± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1.5°C @ 180°C |
± 1.0°C @ 5°C ± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1°C @ 180°C |
± 1.0°C @ 5°C ± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1.5°C @ 180°C |
± 1.0°C @ 5°C ± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1.5°C @ 180°C |
Wattage | 3500 | 3600 | 3600 | 9000 | 12000 |
Relative humidity stability (%) | ±0.3% @ 50°C 50% Rh ±0.3% @ 90°C 90% Rh |
±0.3% @ 50°C 50% Rh ±0.3% @ 90°C 90% Rh |
±0.3% @ 50°C 50% Rh ±0.3% @ 90°C 90% Rh |
±0.5% @ 50°C 50% Rh ±0.5% @ 90°C 90% Rh |
±0.5% @ 50°C 50% Rh ±0.5% @ 90°C 90% Rh |
KK-68 CH | KK-190 CH | KK-340 CH | KK-500 CH | KK-1000 CH | |
---|---|---|---|---|---|
Volume | 68L | 190L | 340L | 500L | 1000L |
Temperature Range | -40°C to +180°C | -40°C to +180°C | -40°C to +180°C | -40°C to +180°C | -40°C to +180°C |
Relative Humidity Range | 10% to 98% | 10% to 98% | 10% to 98% | 10% to 98% | 10% to 98% |
External dimensions (WxHxD) | 650 x 1233 x 796mm | 835 x 1661 x 951 | 835 x 1881 x 1126 | 1035 x 1880 x 1381 | 1235 x 1928 x 1579 |
Internal Dimensions (WxHxD) | 410 x 475 x 350mm | 600 x 615 x 510mm | 600 x 835 x 685mm | 800 x 835 x 800mm | 1000 x 1035 x 1000mm |
Max Capacity | 40 kg | 80 kg | 100 kg | 150 kg | 200 kg |
Temperature stability | ± 0.2°C @ - 40°C ± 0.05°C @ 50°C 50 % Rh ± 0.05°C @ 90°C 90 % Rh ± 0.1°C @ 18°C |
± 0.2°C @ - 40°C ± 0.05°C @ 50°C 50 % Rh ± 0.05°C @ 90°C 90 % Rh ± 0.15°C @ 18°C |
± 0.2°C @ - 40°C ± 0.05°C @ 50°C 50 % Rh ± 0.05°C @ 90°C 90 % Rh ± 0.15°C @ 18°C |
± 0.2°C @ - 40°C ± 0.05°C @ 50°C 50 % Rh ± 0.05°C @ 90°C 90 % Rh ± 0.2°C @ 18°C |
± 0.2°C @ - 40°C ± 0.05°C @ 50°C 50 % Rh ± 0.05°C @ 90°C 90 % Rh ± 0.2°C @ 18°C |
Temperature Uniformity | ± 1°C @ - 40°C ± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 2.5°C @ 180°C |
± 0.2°C @ - 40°C ± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1.5°C @ 180°C |
± 0.2°C @ - 40°C ± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1.5°C @ 180°C |
± 0.5°C @ - 40°C ± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1.5°C @ 180°C |
± 0.5°C @ - 40°C ± 0.3°C @ 50°C 50 % Rh ± 0.3°C @ 90°C 90 % Rh ± 1.5°C @ 180°C |
Wattage | 3500 | 3600 | 3600 | 9000 | 12000 |
Relative humidity stability (%) | ±0.3% @ 50°C 50% Rh ±0.3% @ 90°C 90% Rh |
±0.3% @ 50°C 50% Rh ±0.3% @ 90°C 90% Rh |
±0.3% @ 50°C 50% Rh ±0.3% @ 90°C 90% Rh |
±0.3% @ 50°C 50% Rh ±0.3% @ 90°C 90% Rh |
±0.3% @ 50°C 50% Rh ±0.3% @ 90°C 90% Rh |
KK-340 CHLT F | KK-500 CHLT F | KK-1000 CHLT F | |
---|---|---|---|
Volume | 340L | 500L | 1000L |
Temperature Range | -40°C to +180°C | -40°C to +180°C | -40°C to +180°C |
Relative Humidity Range | 10% to 98% | 10% to 98% | 10% to 98% |
External dimensions (WxHxD) | 835 x 1895 x 1115mm | 1035 x 1900 x 1320mm | 1235 x 1917 x 1595mm |
Internal Dimensions (WxHxD) | 670 x 870 x 685mm | 870 x 870 x 800mm | 1070 x 1070 x 1000mm |
Max Capacity | 100 kg | 150 kg | 200 kg |
Temperature stability | ± 0.7 °C @ - 40°C ± 0.1°C @ +23°C 50 % Rh ± 0.3°C @ +50°C 50 % Rh ± 0.3°C @ +90°C 90 % Rh ± 0.5°C @ +180°C |
± 0.5°C @ -40°C ± 0.2°C @ +23°C 50 % Rh± 0.2°C @ +50°C 50 % Rh ± 0.2°C @ + 90°C 90 % Rh ± 0.5°C @ +180°C |
± 0.5°C @ -40°C ± 0.2°C @ +23°C 50 % Rh ± 0.3°C @ +50°C 50 % Rh ± 0.3°C @ +90°C 90 % Rh ± 0.5°C @ +180°C |
Temperature Uniformity | ± 1.5°C @ - 40°C ± 0.3°C @ +23°C 50 % Rh ± 1.0°C @ + 50 °C 50 % Rh ± 0.7°C @ +90°C 90 % Rh ± 3.5°C @ + 180°C |
± 1.5°C @ -40°C ± 0.5°C @ +23°C 50 % Rh ± 1.0°C @ +50°C 50 % Rh ± 0.5°C @ +90°C 90 % Rh ± 3.0°C @ +180°C |
± 1.5 °C @ -40°C ± 0.5°C @ +23°C 50 % Rh± 1.0°C @ +50°C 50 % Rh ± 0.5°C @ +90°C 90 % Rh ± 3.0 °C @ +180°C |
Wattage | 9500 | 12000 | 15000 |
Relative humidity stability (%) | ± 1 % @ +50°C 50 % Rh ± 1 % @ +90°C 90 % Rh |
± 1.5 % @ +50°C 50 % Rh ± 1 % @ +90°C 90 % Rh |
± 1 % @ +50°C 50 % Rh ± 1 % @ +90°C 90 % Rh |
KK-340 CHLT UF | KK-500 CHLT UF | KK-1000 CHLT UF | |
---|---|---|---|
Volume | 340L | 500L | 1000L |
Temperature Range | -40°C to +180°C | -40°C to +180°C | -40°C to +180°C |
Relative Humidity Range | 10% to 98% | 10% to 98% | 10% to 98% |
External dimensions (WxHxD) | 835 x 1986 x 1576mm | 1035 x 1956 x 1693mm | 1235 x 2156 x 1891mm |
Internal Dimensions (WxHxD) | 670 x 900 x 685mm | 870 x 870 x 800mm | 1070 x 1070 x 1000mm |
Max Capacity | 100kg | 150 kg | 200 kg |
Temperature stability | ± 0.7 °C @ - 40°C ± 0.1°C @ +23°C 50 % Rh ± 0.3°C @ +50°C 50 % Rh ± 0.3°C @ +90°C 90 % Rh ± 0.5°C @ +180°C |
± 0.5°C @ -40°C ± 0.2°C @ +23°C 50 % Rh± 0.2°C @ +50°C 50 % Rh ± 0.2°C @ + 90°C 90 % Rh ± 0.5°C @ +180°C |
± 0.5°C @ -40°C ± 0.2°C @ +23°C 50 % Rh ± 0.3°C @ +50°C 50 % Rh ± 0.3°C @ +90°C 90 % Rh ± 0.5°C @ +180°C |
Temperature Uniformity | ± 1.5°C @ - 40°C ± 0.3°C @ +23°C 50 % Rh ± 1.0°C @ + 50 °C 50 % Rh ± 0.7°C @ +90°C 90 % Rh ± 3.5°C @ + 180°C |
± 1.5°C @ -40°C ± 0.5°C @ +23°C 50 % Rh ± 1.0°C @ +50°C 50 % Rh ± 0.5°C @ +90°C 90 % Rh ± 3.0°C @ +180°C |
± 1.5 °C @ -40°C ± 0.5°C @ +23°C 50 % Rh± 1.0°C @ +50°C 50 % Rh ± 0.5°C @ +90°C 90 % Rh ± 3.0 °C @ +180°C |
Wattage | 18000 | 21000 | 21000 |
Relative humidity stability (%) | ± 1 % @ +50°C 50 % Rh ± 1 % @ +90°C 90 % Rh |
± 1.5 % @ +50°C 50 % Rh ± 1 % @ +90°C 90 % Rh |
± 1 % @ +50°C 50 % Rh ± 1 % @ +90°C 90 % Rh |